Generator JP30
GENERATING SET MODEL (JP30)
Output RatingsPrimeStandby
400-415 V, 3 ph, 50 Hz, 1500 rpm30 KVA33 KVA
24 KW26.4 KW
GENERATING SET MODEL (JP30)
Engine MakePerkins
Engine Model1103A-33G
Governing TypeMechanical
Number of Cylinders3
Cylinder ArrangementVertical in line
Bore and Stroke mm105 x 127
Displacement / Cubic Capacity litres3.3
Induction SystemNaturally Aspirated
Cycle 4 stroke
System CombustionDirect Injection
Compression Ratio19.25:1
RotationClockwise, viewed on front
Cooling SystemWater – cooled
Frequency and Engine Speed50Hz & 1500rpm
PrimeStandby
Gross Engine Power KW (hp)28.2 (37.8)31.0 (41.6)
Fuel Consumption @ 50% load L/hr
@ 75% load L/hr
@ 100% load L/hr
4.07
5.59
7.33


8.01
Total Lubrication System Capacity litres8.38.3
Total Coolant Capacity (Inc. radiator) litres10.210.2
Exhaust Temperature: °C500520
Radiator Cooling Air Flow (Min): m³/sec0.880.88
Combustion Air Flow: m³/min2.162.15
Exhaust Gas Flow: m³/min5.75.8
DIMENSIONS AND WEIGHT
Length cmWidth cmHeight cmWeight Kg (wet)Fuel Tank Litres
17572124813111

STANDARD SPECIFICATIONS

1 – ENGINE

Perkins four stroke heavy duty high-performance industrial type Diesel engine.

2 – ENGINE FILTRATION SYSTEM

  • Air filter
  • Fuel filter
  • Full flow lube oil filter

All filters have replaceable elements

3 – COOLING RADIATOR

Radiator and cooling fan, complete with safety guards, designed to cool the engine at high ambient temperatures.

4 – EXHAUST SYSTEM

Heavy Duty Industrial Exhaust Silencer:
Silencer noise reduction level: 15(dB)
Maximum Allowable Back Pressure: 8.0 @50 Hz / 10.0@ 60Hz

5 – CIRCUIT BREAKER TYPE

ABB 3 pole MCB. (4 pole is optional)

ALTERNATOR DATA
MakeLeroy Somer
ModelTAL 042C
No. of bearings1
Insulation classH
Total Harmonic Contentat no load <3%
– on load < 2%
Ingress ProtectionIP23
Excitation SystemSHUNT
Winding Pitch2/3
AYR ModelR120
Overspeed2250 RPM
Voltage Regulation± 1%
Short Circuit Capacity
AREP or PMG Excitation System Available as Optional
CONTROL PANEL
MakeDeep Sea
ModelDSE6120
The DSE6120 is an Auto Start Control Module for single genset applications. It includes a backlit LCD display which clearly shows the status of the engine all the times. This module can either be programmed using the front panel or by using the DSE configuration suite PC software.
Metering and Alarm Indications:
– Generator frequency
– Underspeed, Overspeed
– Generator volts (L-L, L-N)
– Engine oil pressure
– Engine coolant temperature
– Fuel level (warning or shutdown) – optional
– Hours run counter
– Battery volts
– Fail to start/stop
– Emergency stop
– Failed to reach loading voltage/frequency
– Charge fail
– Loss of magnetic pick-up signal – optional
– Low DC voltage
– CAN diagnostics and CAN fail/error

ALL INSPIRED DESIGN TO MEET YOUR NEEDS

AVAILABLE OPTIONS AND ACCESSORIES
We offer a range of optional features and accessories to tailor our generating sets to meet your power needs.

OPTIONS
* A variety of generating set control and synchronizing panels
* Additional protection alarms and shutdowns
* Water fuel separator
* Water jacket heater
* Battery charger

ACCESSORIES
* Genuine spare parts
* Load banks
* Auxiliary fuel tanks
* Manual & automatic transfer switches

STANDARD SPECIFICATIONS

6. FUEL SYSTEM
On Generating Sets up to 650 KVA, the baseframe design is incorporated with an integral fuel tank with a capacity of approx. 8 hours running at Full Load. The tank is supplied complete with full cap breather, fuel feed and return lines to the Engine and drain plug.

7. ALTERNATOR
7.1 INSULATION SYSTEM
– The insulation system is Class H.
– All windings are impregnated in either a triple dip thermosetting liquid, oil and acid resisting polyester varnish or vaccum pressure impregnated with a special polyester resin.
– Heavy coat of antitracking varnish additional protection against moisture or condensation.

7.2 AUTOMATIC VOLTAGE REGULATOR (AVR)
The fully sealed Automatic Voltage Regulator maintains the Voltage Regulation at 1% Nominal adjustment by means of a trim pot incorporated on the AVR.

7.3 MOTOR STARTING
An overload capacity equivalent to 300% of the Full Load impedance at zero Power Factor can be sustained for 10 seconds, when PMG option is fitted.

8. MOUNTING ARRANGEMENT
8.1 BASE FRAME
The complete Generating Set is mounted as a whole on a heavy duty fabricated steel Baseframe.

8.2 COUPLING
The Engine and Alternator are directly coupled by means of an SAE  flange. The Engine flywheel is flexibly coupled to the. Alternator rotor.

8.3 ANTI-VIBRATION MOUNTING PADS
Anti-Vibration pads are affixed between the Engine/ Alternator feet and the Baseframe thus ensuring complete vibration isolation of the rotating assembly.

8.4 SAFETY GUARDS
The Fan & Fan Drive along with the Battery Charging Alternator are Safety Guard protected for personnel protection.

9. FACTORY TESTS
* The Generating set is load tested before dispatch
* All protective devices control functions and site load conditions are simulated, The generator and its systems are checked before dispatch.

10. EQUIPMENT FINISHING
All mild steel components are fully degreased and painted with powder coated paint to ensure maximum scuff resistance and durability.

11. DOCUMENTATIONS
Operation & Maintenance manual, Circuit wiring diagrams, and Commissioning / Fault Finding Instruction leaflets are accompanied with the Generator.

12. QUALITY STANDARDS
The equipment meets the following standards: BS4999, BS5000, BS5514, IEC 60034, VDEO530, NEMA MG 1 22 and ISO 8528

13. WARRANTY
All of the Generating Sets are covered under a warranty policy for a period of 12 months. Warranty of the equipment is in line with manufacturer’s warranty terms & conditions.

In line with continuous product development, we reserve the right to change specifications without notice.